Select your language

Case studies

 


Flow monitoring in open channels
requires measurements distributed over time and a configuration adapted to the conditions of each individual section.

Changes in water level, the presence of vegetation and sediment deposits can alter measurement conditions and make it necessary to use different technologies along the same network.

In this application example, the system consists of submerged sensors and non-contact radar instruments, connected to control units for data acquisition and transmission.

Configuration of measurement points

In sections where conditions allow installation directly in the water, a submerged velocity sensor can be combined with water level measurement.

Where access to the section or the presence of transported material makes it preferable to keep the instrumentation outside the water, surface velocity radar sensors and radar level sensors can be used.

The technology is selected after surveying the channel cross-section and verifying the operating range of the instruments.

At points affected by vegetation, access and cleaning procedures must also be planned so that measurement conditions can be maintained over time.

Flow calculation

The reconstruction of flow rate uses the geometry of the section, the water level and a velocity representative of the flow.

For surface radar measurements, the relationship between surface velocity and mean flow velocity must be defined and verified according to the characteristics of the specific site.

Accurate knowledge of the hydraulic cross-section geometry is therefore essential for converting level and velocity measurements into flow values.

Data recording and volume calculation

The system stores the data required to verify the calculation and allows any invalid readings or periods in which reliable measurement conditions are not available to be identified.

Cumulative volumes can be calculated by integrating the recorded flow rates over time, taking into account any intervals without valid data.

The availability of time series makes it possible to follow the flow trend at the different points of the network and compare variations over time.

Remote data access

The measurements can be transmitted to the METRA monitoring platform, where they are organized into historical series for the different measurement points.

Comparing the acquired data with the operation of flow control structures helps interpret variations in level, velocity and flow throughout the network more accurately.

Station inspection and maintenance

Automatic monitoring should be complemented by periodic inspection of the cross-section and the instrumentation.

Vegetation, deposits, changes in bed geometry or accumulation of transported material can alter hydraulic conditions and affect measurement quality.

This approach makes it possible to maintain a consistent flow monitoring network even when different points require different measurement technologies and maintenance procedures.